Fibre Glass & Asbestos Insulated Cables

Fibre Glass & Asbestos Insulated Cables

WhatsApp us

ALECTOCAB™ Fibre Glass & Asbestos Insulated Cables are specialised high-temperature cable solutions designed for industrial electrical installations where conventional insulation materials may not withstand elevated operating temperatures.

Available with fibreglass braided insulation and specialised asbestos-insulated constructions, these cables are designed to provide thermal stability, electrical insulation and mechanical protection under specified operating conditions.

The range includes insulation Classes B, F, H and C, with corresponding temperature classifications starting at 130°C and extending above 180°C, depending on the selected cable construction.

Conductor options include plated copper, nickel, thermocouple alloys and other specialised materials. Braided and varnish-impregnated constructions are available for enhanced insulation integrity and handling characteristics.

Suitable for selected high-temperature electrical equipment, industrial heating systems, temperature measurement circuits and applications involving PTFE or silicone rubber insulation systems.

Customised conductor configurations, insulation constructions and bulk project supply can be discussed according to technical requirements. Asbestos-containing variants are subject to applicable legal, safety and handling restrictions.

High-Temperature Insulated Cables for Industrial Electrical & Thermal Applications

ALECTOCAB™ Fibre Glass & Asbestos Insulated Cables are specialised cable solutions designed for high-temperature industrial environments where conventional electrical insulation materials may not provide suitable thermal performance.

Industrial electrical equipment operating near heating elements, furnaces, temperature measurement systems and other heat-generating machinery often requires cable constructions capable of maintaining electrical insulation under elevated temperature conditions.

ALECTOCAB™ offers fibreglass-insulated cable constructions using braided glass-fibre insulation to provide thermal stability, electrical insulation and additional mechanical reinforcement for suitable industrial applications.

Fibreglass insulation is valued for its ability to withstand elevated temperatures and maintain useful insulating properties when appropriately designed and applied. The braided construction also helps provide physical coverage around the conductor while accommodating different cable configurations.

Selected fibreglass cable constructions are available with varnish impregnation. The impregnation process can improve braid cohesion, reduce fibre fraying and support insulation integrity, depending on the varnish formulation and operating environment.

The range includes insulation systems associated with thermal Classes B, F, H and C. These classifications correspond to different thermal endurance levels, beginning at 130°C and extending beyond 180°C for suitable insulation systems.

ALECTOCAB™ offers conductor options including plated copper, nickel, thermocouple conductors and other specialised conductor materials. The appropriate conductor is selected according to electrical conductivity, temperature exposure, corrosion resistance and application requirements.

Specialised asbestos-insulated cable constructions may also be considered where legally permitted and specifically required. Because asbestos presents serious health hazards when fibres are released and inhaled, such products require appropriate regulatory verification, controlled handling and documented safety procedures. Fibreglass and other asbestos-free high-temperature insulation systems should be preferred wherever technically suitable.

These high-temperature cable solutions may also be specified alongside PTFE, silicone rubber and other heat-resistant insulation systems, depending on the operating temperature and electrical requirements.

Whether you require Fibreglass Braided Cables, Varnished Fibreglass Insulated Wires, High-Temperature Electrical Cables or specialised conductor configurations, ALECTOCAB™ offers application-specific cable solutions with technical guidance and bulk project supply options.

Key Features and Benefits

High-Temperature Insulation

Designed for electrical applications requiring insulation materials suitable for elevated temperatures where conventional cable insulation may be inadequate.

Fibreglass Braided Construction

Fibreglass braiding provides thermal insulation characteristics and physical coverage around the conductor for suitable high-temperature applications.

Insulation Classes B, F, H & C

Available with insulation systems associated with different thermal classes, allowing cable selection according to the required temperature classification.

Temperature Classifications from 130°C to Above 180°C

Suitable insulation systems can be selected for thermal classifications beginning at 130°C and extending above 180°C, subject to the complete cable construction.

Plated Copper Conductor Options

Plated copper conductors are available for selected applications requiring dependable electrical conductivity and suitable surface protection.

Nickel & Specialised Conductors

Nickel and other specialised conductor materials can be considered for applications with demanding temperature or environmental requirements.

PTFE Insulation Options

PTFE-insulated constructions are available for applications requiring suitable high-temperature insulation characteristics and resistance to selected chemicals.

XLPE Insulation Options

XLPE insulation provides an alternative construction for applications requiring the electrical and thermal characteristics of cross-linked polyethylene.

Thermocouple Conductor Options

Compatible thermocouple conductor configurations are available for selected industrial temperature measurement and instrumentation applications.

Customised Cable Configurations

Conductor materials, insulation classes, braided constructions, varnish treatment and cable dimensions can be discussed for specific industrial requirements.

Technical Specifications

ComponentSpecification
Product TypeFibre Glass & Asbestos Insulated Cable
Primary InsulationFibreglass
Specialised InsulationAsbestos (Regulated, Where Legally Permitted)
Insulation ConstructionBraided
Insulation TreatmentVarnish Impregnation Option
Thermal Insulation ClassesB / F / H / C
Class B Thermal Classification130°C
Class F Thermal Classification155°C
Class H Thermal Classification180°C
Class C Thermal ClassificationAbove 180°C
Conductor MaterialPlated Copper / Nickel / Thermocouple / Special Conductors
Cable ConstructionBraided / Varnished Options
Thermal PerformanceDependent on Insulation System and Cable Design
Compatible Insulation SystemsPTFE / Silicone Rubber / Other High-Temperature Materials
Primary FunctionElectrical Insulation in Elevated-Temperature Environments
Cable ConfigurationStandard / Application-Specific
Supply TypeOEM / Project / Bulk Enquiries

Thermal insulation class does not automatically establish the maximum continuous operating temperature of the finished cable. The conductor, impregnation material, insulation construction and other components must all be suitable for the specified operating conditions.

Why Choose ALECTOCAB™ Fibre Glass & Asbestos Insulated Cables?

  • Fibreglass braided insulation for high-temperature applications
  • Insulation system options associated with Classes B, F, H and C
  • Thermal classifications from 130°C to above 180°C
  • Plated copper conductor options
  • Nickel and specialised conductor materials
  • Thermocouple conductor configurations
  • Braided and varnish-impregnated constructions
  • Application-specific high-temperature cable solutions
  • Compatibility with selected PTFE and silicone rubber insulation systems
  • Customised configurations and OEM or bulk project enquiries

Ordering Information

  • Required insulation type: Fibreglass or other specified high-temperature insulation
  • Required thermal class: B / F / H / C
  • Operating temperature: Continuous and maximum exposure temperature
  • Conductor material: Plated Copper / Nickel / Thermocouple / Special Alloy
  • Conductor size: Required cross-sectional area or diameter
  • Cable configuration: Number of cores and required construction
  • Cable configuration: Number of cores and required construction
  • Insulation construction: Braided / Varnish-Impregnated
  • Additional insulation requirements: PTFE / Silicone Rubber / Other Materials
  • Electrical requirements: Voltage rating and relevant performance specifications
  • Supply requirements: Cable length, quantity and intended installation conditions

For any request involving asbestos-containing materials, legal permissibility and occupational safety requirements must be established before considering supply.

Our team can review your technical requirements and discuss suitable high-temperature cable configurations for your project.

What are Fibre Glass Insulated Cables?

Fibre Glass Insulated Cables are electrical cables that use glass-fibre insulation, often in braided form, for applications requiring suitable electrical insulation at elevated temperatures.

They are associated with high-temperature electrical equipment, industrial heating systems, temperature measurement connections and specialised installations where conventional insulation may not be suitable. Asbestos-containing variants require separate legal and safety assessment.

 

The stated insulation classifications include Class B at 130°C, Class F at 155°C, Class H at 180°C and Class C above 180°C. The finished cable’s permissible operating temperature must be confirmed separately.

Fibreglass braiding provides thermal stability, electrical insulation and physical coverage around conductors, making it useful in suitable high-temperature cable constructions.

It is a construction in which fibreglass braiding is treated with a suitable insulating varnish to help improve braid cohesion, reduce fraying and support the insulation’s specified performance.

The specified range includes plated copper, nickel, thermocouple conductors and other specialised conductor materials.

Yes. Suitable constructions with the correct thermocouple conductor alloys can be considered for compatible temperature measurement circuits.

Fibreglass insulation commonly uses woven or braided glass fibres, while PTFE is a fluoropolymer insulation material. Their thermal, electrical, mechanical and environmental characteristics differ, so selection depends on the application.

Asbestos-containing materials can release hazardous fibres, especially when disturbed, cut or damaged. Handling and supply are subject to applicable legal restrictions and occupational safety controls. Asbestos-free alternatives should be preferred wherever suitable.

Yes. Nilesh Enterprises accepts enquiries for customised fibreglass-insulated cable configurations, specialised conductor materials and OEM or bulk project requirements, subject to technical feasibility and applicable regulations.

© ALECTOCAB™ is a trademark of Nilesh Enterprises. All Rights Reserved.