PCM Cables

PCM Cables

WhatsApp us

ALECTOCAB™ PCM (Pulse Code Modulation) Cables are designed for reliable digital signal and data transmission between control rooms, transmitters and antenna installations.

Constructed using 99.9% pure annealed bare copper conductors, these cables feature individually and overall Aluminium Mylar screened pairs, drain wire and precision braided shielding to help minimize electromagnetic interference, crosstalk and external electrical noise.

Available in 1 to 16 pair configurations, with 120Ω ±10 impedance at 1 MHz, high insulation resistance, dielectric strength and flame-retardant PVC outer sheathing.

Suitable for selected telecommunications, digital communication and signal transmission applications. Customized pair configurations, cable lengths and bulk project supply are available.

Reliable Shielded Cables for Digital Communication & Signal Transmission Systems

ALECTOCAB™ PCM (Pulse Code Modulation) Cables are designed for dependable digital signal and data transmission across telecommunication networks, control rooms, transmitter installations and antenna communication systems.

Constructed using 99.9% pure annealed bare copper conductors, these cables provide reliable electrical conductivity for communication and signal transmission applications. The copper conductors are arranged in twisted pairs to support consistent signal transmission and help reduce interference between adjacent circuits.

To improve signal protection, ALECTOCAB™ PCM Cables incorporate individual pair and overall Aluminium Mylar screening. This multi-layer screening construction helps minimize electromagnetic interference (EMI), crosstalk and external electrical noise, supporting reliable communication in electrically demanding environments.

Additional shielding features include drain wire and precision braided shielding, which provide further protection against unwanted electrical interference and support appropriate screen grounding arrangements.

The cables feature a flame-retardant PVC outer sheath for protection during installation and operation in suitable communication environments.

Designed with a nominal characteristic impedance of 120Ω ±10 at 1 MHz, these PCM cables are intended for compatible digital communication and signal transmission systems.

ALECTOCAB™ PCM Cables are available in configurations ranging from 1 pair to 16 pairs, with colour-coded conductors for convenient pair identification, installation and termination.

With high insulation resistance and dielectric strength characteristics, these cables support dependable electrical insulation for their intended communication applications.

Whether you require shielded PCM cables for telecommunication infrastructure, control room connections, transmitter systems or antenna installations, ALECTOCAB™ offers practical multi-pair communication cable solutions with customized configurations, lengths and bulk supply options.

Key Features and Benefits

99.9% Pure Annealed Bare Copper Conductors

Constructed using 99.9% pure annealed bare copper conductors to provide dependable electrical conductivity for digital signal and communication applications.

Individually Shielded Pairs

Individual Aluminium Mylar screening around cable pairs helps reduce interference and crosstalk between adjacent communication circuits.

Overall Aluminium Mylar Screening

Overall Aluminium Mylar screening provides an additional shielding layer to help protect signals against external electromagnetic interference.

Precision Braided Shielding

Braided shielding provides supplementary protection against electrical noise and electromagnetic interference, depending on the selected cable construction.

Drain Wire for Screen Connection

An integrated drain wire provides an electrical connection to the metallic screening for appropriate grounding arrangements.

120Ω ±10 Impedance at 1 MHz

Designed with a nominal characteristic impedance of 120Ω ±10 at 1 MHz for compatible digital communication and signal transmission applications.

High Insulation Resistance

Cable insulation is designed to provide high electrical insulation resistance and reduce unwanted leakage between conductors.

High Dielectric Strength

Insulation construction supports electrical separation between conductors and reliable performance under the cable's specified operating conditions.

Flame-Retardant PVC Outer Sheath

Flame-retardant PVC outer sheathing provides cable protection and is suitable for installations requiring the specified sheath construction.

Multiple Pair Configurations

Available in configurations ranging from 1 pair to 16 pairs to accommodate different communication and signal transmission requirements.

Colour-Coded Pair Identification

Colour-coded pairs help simplify conductor identification, cable termination, installation and maintenance.

Customized Cable Supply

Custom pair configurations, cable lengths and packaging options can be discussed for OEM, contractor and bulk project requirements.

Technical Specifications

ComponentSpecification
Product TypePCM / Pulse Code Modulation Cable
Conductor MaterialAnnealed Bare Copper
Copper Purity99.90%
Cable ConstructionMulti-Pair
Number of Pairs1 to 16 Pairs
Pair FormationTwisted Pairs
Individual Pair ScreeningAluminium Mylar Tape
Overall ScreeningAluminium Mylar Tape
Additional ShieldingPrecision Braided Shielding
Drain WireAvailable
Characteristic Impedance120Ω ±10 at 1 MHz
Insulation ResistanceHigh Insulation Resistance
Dielectric StrengthHigh Dielectric Strength
Pair IdentificationColour-Coded
Outer SheathFlame-Retardant PVC
Cable LengthStandard / Customized
PackagingAs per Requirement
Primary ApplicationsDigital Communication / Telecommunications / Signal Transmission
Supply TypeOEM / Project / Bulk Supply

Final conductor dimensions, insulation material, screen coverage, drain wire construction, braid coverage, electrical test values and cable dimensions depend on the selected cable configuration and applicable product datasheet.

Why Choose ALECTOCAB™ PCM Cables?

  • 99.9% pure annealed bare copper conductors
  • Individual pair Aluminium Mylar screening
  • Overall Aluminium Mylar screening
  • Precision braided shielding for additional EMI protection
  • Drain wire for screen connection
  • 120Ω ±10 characteristic impedance at 1 MHz
  • High insulation resistance
  • High dielectric strength
  • Flame-retardant PVC outer sheath
  • Multi-pair configurations from 1 to 16 pairs
  • Colour-coded pairs for convenient identification
  • Suitable for compatible digital communication and telecommunication systems
  • Customized cable lengths and packaging
  • OEM, contractor and bulk project supply

Ordering Information

  • Required number of pairs: 1 to 16 pairs
  • Conductor material: Annealed Bare Copper
  • Required conductor size or diameter
  • Individual pair screening requirement
  • Overall screening requirement
  • Braided shielding requirement
  • Drain wire requirement
  • Required characteristic impedance
  • Insulation resistance and dielectric strength requirements
  • Outer sheath: Flame-Retardant PVC
  • Packaging preference
  • Required cable length
  • Total order quantity
  • Intended communication application and installation environment

Our team can review your technical requirements and assist with suitable PCM Cable configurations for your communication project.

What is a PCM Cable?

A PCM (Pulse Code Modulation) Cable is a communication cable designed for transmitting digital signals between compatible telecommunication, transmission and control equipment.

PCM Cables are used for digital signal transmission in compatible telecommunications, control room connections, transmitter installations and antenna communication systems.

ALECTOCAB™ PCM Cables use 99.9% pure annealed bare copper conductors for dependable electrical conductivity.

Yes. These cables feature individual pair and overall Aluminium Mylar screening, along with drain wire and braided shielding in the specified construction.

Individual pair screening helps reduce crosstalk and electrical interference between adjacent communication circuits.

Overall screening helps reduce the effects of external electromagnetic interference on the cable’s communication signals.

Braided shielding provides additional protection against electromagnetic interference and unwanted electrical noise.

The specified characteristic impedance is 120Ω ±10 at 1 MHz.

ALECTOCAB™ PCM Cables are available in configurations ranging from 1 pair to 16 pairs.

Yes. Colour-coded pairs help simplify identification, installation, termination and maintenance.

© ALECTOCAB™ is a trademark of Nilesh Enterprises. All Rights Reserved.